Last edited by Gok
Thursday, July 30, 2020 | History

2 edition of flame photometric analysis of total sodium, potassium and calcium in the fetal golden hamster (Cricetus auratus) found in the catalog.

flame photometric analysis of total sodium, potassium and calcium in the fetal golden hamster (Cricetus auratus)

Marvin Francis Hill

flame photometric analysis of total sodium, potassium and calcium in the fetal golden hamster (Cricetus auratus)

by Marvin Francis Hill

  • 219 Want to read
  • 8 Currently reading

Published .
Written in English

    Subjects:
  • Photometry.,
  • Biochemistry.,
  • Hamsters.

  • Edition Notes

    Statementby Marvin Francis Hill.
    The Physical Object
    Pagination23 leaves, bound :
    Number of Pages23
    ID Numbers
    Open LibraryOL14305957M

    Although it is doubtful that any reasonably rapid, purely flame photometric, method can ever equal the best flame-supported gravimetric techniques in determinations of major alkali constituents, procedures were worked out whereby rubidium and cesium can be determined with improved precision, and the accuracy of sodium and potassium. A total of 15 junk foods were processed and analyzed for estimating the sodium content in them by Flame Photometry. Based on the analysis the samples were categorized into low, moderate and high sodium containing foods. The analysis helps in creating awareness among all the generations to reduce the sodium intake in order to prevent problems.

    An abnormal increase of potassium (hyperkalemia) or decrease of potassium (hypokalemia) can profoundly affect the nervous system and heart, and when extreme, can be fatal. The normal blood potassium level is - millimoles/liter (mmol/l). Sodium (Na) is the major extracellular cation and it plays a role in body fluid distribution. , , , , and mL of the calcium stock solution to the beakers and mix thoroughly. The concentrations of calcium in these standards should be calculated. Set up the flame atomic spectrophotometer as described in the operating instructions. Measure the full set of standards and unknown samples before switching to another element.

    1. The methods of using the Perkin-Elmer flame photometer for the determination of the sodium, potassium, amd calcium content of wines have been described. 2. The sodium content of California table and dessert wines has been measured. It varies from 26 to mg. per liter, aver and is generally lower in table wines than in dessert wines.   Human blood is studied using many parameters, one of which is the sodium concentration. Flamephotometric and potentiometric methods suitable for determining sodium concentration in plasma, serum, and whole blood are considered. An overview of the indicated methods and results of comparison tests on the methods are presented.


Share this book
You might also like
Weave and spin

Weave and spin

situation in Asia.

situation in Asia.

Two boots and a polybag

Two boots and a polybag

Formation of U.S. Security Assistance Policy

Formation of U.S. Security Assistance Policy

coordinated reform of tariffs and domestic indirect taxes

coordinated reform of tariffs and domestic indirect taxes

Military journal of the American revolution

Military journal of the American revolution

The master of sound

The master of sound

University finances

University finances

twenties in Vogue

twenties in Vogue

Makers of the Modern Theological Mind

Makers of the Modern Theological Mind

theory of indicative planning

theory of indicative planning

The Great Sand Sea in Egypt, Volume 59

The Great Sand Sea in Egypt, Volume 59

Applique

Applique

Wildlife on coal island

Wildlife on coal island

ABC for book-collectors

ABC for book-collectors

Flame photometric analysis of total sodium, potassium and calcium in the fetal golden hamster (Cricetus auratus) by Marvin Francis Hill Download PDF EPUB FB2

A flame photometric analysis of total sodium, potassium and calcium in the fetal golden hamster (Cricetus auratus)Author: Marvin Francis Hill. Flame photometric analysis of sodium, potassium calcium in the golden hamster (Mesocricetus auratus) from birth to the fourteenth postnatal weekAuthor: Marvin Francis Hill.

The flame photometric determination of sodium and potassium in plant ash extracts has been studied with particular reference to interferences; the instrument used was a Beckman spectrophotometer model DU, with a flame attachment of the total consumption burner by: 8.

The flame photometric determination of sodium, potassium and calcium in nickel-alumina catalysts E. Pitt, Analyst,88, DOI: /AN Flame photometric and atomic absorption determination of calcium, potassium, and sodium in Ringer's solution and injection and in lactated Ringer's solution.

Weeks JF Jr. Authentic and commerical counterparts of Ringer's solution and lactated Ringer's solution were analyzed by 14 by: 1. Flame Photometric Determination of Manganese in Copper and Steel Alloys. Johnson and P. Lott Analytical Chemistry 35 (11), Flame-photometric determination of sodium and potassium in manganese ores B.

Russell, Analyst,91, DOI: /AN SODIUM AND POTASSIUM BY FLAME PHOTOMETRY Submitted by: PAULINE M. HALD, Department of Internal Medicine, see MS Yale University School of Medicine, New Haven, Connecticut W. BURKETT MASON, Department of Biochemistry and Atomic Energy Project, School of Medicine and Dentistry, University of Rochester, Rochester, New York Introduction and Principles In recent years flame.

BWB Technologies UK Ltd. A guide to Flame Photometer Analysis. Biefeld P. Determination of Sodium, Potassium, Magnesium And Iron Oxides In Portland Cement By Flame Photometry, Research Laboratory Office of Testing and Research Report No.

Worth H.G. A comparison of the measurement of sodium and potassium. Flame Photometric Analysis of Sodium and Potassium in Nanogram Samples of Mammalian Nervous Tissue Journal of Neurochemistry, ; 15 (7)– 7.

Worth H.G., A comparison of the measurement of sodium and potassium by flame photometry and ion-selective electrode". Ann. Clin. Biochem. ; 22, Potassium content 0 20 40 60 80   Determination of Potassium, Sodium, and Total Alkalies in Portland Cement, Fly Ash, Admixtures, and Water of Concrete by a Simple Flow Injection Flame Photometric System.

Journal of Automated Methods and Management in Chemistry, DOI: // Paweł Kościelniak, Joanna Kozak. Set up the flame photometer as detailed in the instruction manual for the element under test. Aspirate the diluent solution and set the zero reading. Aspirate 6, 4 and 2ppm standards into the flame photometer.

Plot a standard curve of sodium (or potassium. A method is described for the determination of sodium and potassium in blood serum and urine by means of the flame photometer.

Sodium is determined by diluting serum or urine times with distilled water, by spraying the solution obtained into a flame fed by a mixture of butane and air and measuring the intensity of the yellow sodium light with a selenium barrier‐layer photocell.

A simple flow injection with flame photometric detection has been developed for determination of sodium, potassium, and total alkalies in portland cement, fly ash, admixtures, and water of concrete. The convenience and accuracy of flame photometric determinations of sodium and potassium in biological fluids (1, 2) have suggested the de- sirability of extending these advantages to determinations of calcium.

Since calcium emission lines are much less intense than those of sodium and potassium (3), the samples of diluted serum (1: FLAME PHOTOMETRIC DETERMINATION OF CALCIUM, MAGNESIUM, AND POTASSIUM IN CANNED TOMATOES. LUH. Department of Food Technology University of California, Davis, Calif.

Search for more papers by this author. NIKETIC. Department of Food Technology University of California, Davis, Calif.

KINGSLEY GR, SCHAFFERT RR. Micro flame photometric determination of sodium, potassium and calcium in serum with solvents. J Biol Chem. Feb; (2)– LLAURADO JG. Simplified estimation of calcium in biological materials by flame photometry.

J Clin Pathol. May; 7 (2)– [PMC free article] MACINTYRE I. Photoelectric flame photometry, a branch of atomic spectroscopy is used for inorganic chemical analysis for determining the concentration of certain metal ions such as sodium, potassium, lithium, calcium, Cesium, etc. In flame photometry the species (metal ions) used in the spectrum are in the form of atoms.

The International Union of Pure and. DETERMINATION OF SODIUM, POTASSIUM, CALCIUM AND LITHIUM IN A WHEAT GRASS BY FLAME PHOTOMETRY K.

Shah*, P. Kapupara, T. Desai R. College Of Pharmacy, Kasturbadham, Rajkot, Gujarat, India ABSTRACT Wheat grass is well known and easily available plant and being used for treatment of various diseases since many decades.

The complex matrix (of different concentrations) effect in the ICP-AES determination of sodium, potassium, magnesium and calcium was studied. Interference due to. enhancement effect on the emission spectra of sodium, potassium, and especially of calcium.

The use of an aqueous solvent for the direct microphotometric deter- mination of sodium, potassium, and calcium in a single biological specimen has been reported (4).

Method Reagents Mixed stock standard. of sodium, of potassium.Flame Photometer Protocol: PA Determination of Potassium in Granular and Powdered Inorganic Fertilizers Introduction Fertilizers are chemical compounds applied to promote plant and fruit growth. Fertilizers are usually applied either through the soil or, by foliar feeding for uptake through leaves.urement of potassium.

To reduce the risk and to improve the quality of compounding, we used an automated compounding device but, even in this case, the acceptance criterion for sodium and potassium determination was not Total Parenteral Nutrition, Atomic Emission Spectrometry.

1. Introduction.